Under the 2019 Residential Code of Ohio, a deck ledger is fastened to the house band joist with half-inch lag screws or bolts, spaced by joist span from Table 507.9.1.3(1): for joists spanning 10 ft 1 in to 12 ft, lags go every 15 inches and through-bolts every 29 inches. The fasteners are staggered top to bottom, held set distances from the board edges, and the ledger is flashed so water can’t reach the house framing. Nails alone don’t count. Our deck permits and codes guide for the tri-state covers the permit side; this post is about the one connection that holds an attached deck to your house.
The ledger matters because it is where most serious deck problems start. NADRA, the North American Deck and Railing Association, calls the ledger board a common source of deck failure in its homeowner checklist, and the older decks we tear off around Cincinnati back that up. Below are the numbers a plan reviewer checks, the walls a ledger can’t go on, and what we look for when a homeowner asks us whether an existing ledger is sound.
The ledger matters because it is where most serious deck problems start. NADRA, the North American Deck and Railing Association, calls the ledger board a common source of deck failure in its homeowner checklist, and the older decks we tear off around Cincinnati back that up. Below are the numbers a plan reviewer checks, the walls a ledger can’t go on, and what we look for when a homeowner asks us whether an existing ledger is sound.
Quick answer
10 min read
Fasteners1/2 in. lag screws or bolts, per table
Spacing basisJoist span (RCO Table 507.9.1.3(1))
Example, 10–12 ft joistsLags 15 in. o.c.; bolts 29 in. o.c.
PatternStaggered top to bottom
FlashingRequired where a deck meets a wood-frame wall
Not allowedNails alone; brick veneer; cantilevered floors
Inspected atFraming inspection, before decking
How the Ohio code wants a ledger attached
The Ohio code asks for a ledger bolted or lagged through the house sheathing into the band joist on a set schedule, with the connection designed to resist both vertical and horizontal movement. The City of Columbus summarizes it in a building department notice on decks that quotes the Residential Code of Ohio: decks attached to the structure “shall be designed and installed to resist both vertical and horizontal movement”, and the attachment can’t rely on toenails or on nails that can pull out. The same notice quotes the flashing rule, covered below.
The detailed schedule sits in Section R507.9, and Franklin County’s deck permit guide reproduces the two tables a reviewer uses. The first sets fastener spacing by joist span. The second sets how close fasteners can sit to the top, bottom and ends of the ledger and the band joist. Both assume a 40 psf live load, a 10 psf dead load and a snow load of 40 psf or less, which covers an ordinary deck. A hot tub, a roof or an outdoor kitchen on the deck changes the loads and moves the design out of the table and onto an engineered connection.
Ohio’s code is built on the 2018 International Residential Code, the same base Indiana uses for its 2020 code, and Kentucky’s 2018 code sits on the 2015 edition. The deck ledger rules in all three trace back to that model code, though we always draw to the edition your county enforces.
The detailed schedule sits in Section R507.9, and Franklin County’s deck permit guide reproduces the two tables a reviewer uses. The first sets fastener spacing by joist span. The second sets how close fasteners can sit to the top, bottom and ends of the ledger and the band joist. Both assume a 40 psf live load, a 10 psf dead load and a snow load of 40 psf or less, which covers an ordinary deck. A hot tub, a roof or an outdoor kitchen on the deck changes the loads and moves the design out of the table and onto an engineered connection.
Ohio’s code is built on the 2018 International Residential Code, the same base Indiana uses for its 2020 code, and Kentucky’s 2018 code sits on the 2015 edition. The deck ledger rules in all three trace back to that model code, though we always draw to the edition your county enforces.
Ledger bolt and lag spacing by joist span
Spacing tightens as the joists get longer, because a longer joist delivers more load to every foot of ledger. A deck with 8-foot joists can have half-inch lags 23 inches apart; stretch the joists to 16 feet and the lags close up to 11 inches. Through-bolts with nuts and washers carry more per fastener, so they can be spaced wider. The figures below are on-center spacing from Table 507.9.1.3(1) as reproduced by Franklin County.
Two footnotes matter on site. The tip of a lag screw has to pass fully beyond the inside face of the band joist, so a short lag that only grabs the outer half of the rim doesn’t qualify. And the sheathing sandwiched between ledger and band joist is capped: half an inch of wood structural panel or solid lumber in the first two columns, and up to an inch in the last column, where gypsum, fiberboard or foam sheathing is also allowed.
Two footnotes matter on site. The tip of a lag screw has to pass fully beyond the inside face of the band joist, so a short lag that only grabs the outer half of the rim doesn’t qualify. And the sheathing sandwiched between ledger and band joist is capped: half an inch of wood structural panel or solid lumber in the first two columns, and up to an inch in the last column, where gypsum, fiberboard or foam sheathing is also allowed.
On-center spacing of ledger fasteners, 2019 RCO Table 507.9.1.3(1) (40 psf live, 10 psf dead)
| Joist span | 1/2 in. lag, 1/2 in. max sheathing | 1/2 in. bolt, 1/2 in. max sheathing | 1/2 in. bolt, 1 in. max sheathing |
|---|---|---|---|
| 6 ft and less | 30 in. | 36 in. | 36 in. |
| 6 ft 1 in. to 8 ft | 23 in. | 36 in. | 36 in. |
| 8 ft 1 in. to 10 ft | 18 in. | 34 in. | 29 in. |
| 10 ft 1 in. to 12 ft | 15 in. | 29 in. | 24 in. |
| 12 ft 1 in. to 14 ft | 13 in. | 24 in. | 21 in. |
| 14 ft 1 in. to 16 ft | 11 in. | 21 in. | 18 in. |
| 16 ft 1 in. to 18 ft | 10 in. | 19 in. | 16 in. |
Edge distances and the stagger
Table 507.9.1.3(2) keeps fasteners at least 2 inches from the top edge of the ledger, 3/4 inch from its bottom edge and 2 inches from its ends, and on the house side at least 3/4 inch from the top of the band joist and 2 inches from its bottom. Rows sit 1 5/8 inches apart at minimum and 5 inches at most, and the fasteners alternate between upper and lower rows along the run. Getting those distances wrong splits the wood around the bolt, which is why the framing inspector measures them.
Elevated composite deck with black aluminum balusters along a brick and siding home
Flashing: keeping water off the house framing
Flashing is required wherever a deck attaches to a wood-frame wall, and its job is to stop water from reaching the band joist the ledger is bolted to. The Columbus notice quotes Section 703.8: approved corrosion-resistive flashing must keep water out of the wall cavity and off structural members where decks or stairs attach. The ledger table in Franklin County’s guide repeats the point in its first footnote: ledgers are flashed to keep water from contacting the house band joist.
This is where Cincinnati weather earns its reputation. Rain and snowmelt run down the siding and land on top of the ledger, and without a flashing path out, the water sits in the joint between the ledger and the house. The band joist behind it is untreated framing, and it rots from the outside in where nobody can see it. Good flashing works like shingles on a roof: each layer laps over the one below it, so water is always led outward and never into the wall. The flashing detail is drawn on our plans, and the framing inspector sees it installed before the decking covers anything.
This is where Cincinnati weather earns its reputation. Rain and snowmelt run down the siding and land on top of the ledger, and without a flashing path out, the water sits in the joint between the ledger and the house. The band joist behind it is untreated framing, and it rots from the outside in where nobody can see it. Good flashing works like shingles on a roof: each layer laps over the one below it, so water is always led outward and never into the wall. The flashing detail is drawn on our plans, and the framing inspector sees it installed before the decking covers anything.
Fasteners that last in treated lumber
Treated lumber is hard on plain steel, so the connection hardware needs corrosion protection. The Town of Lowell, Indiana, in its residential deck guide written on the 2018 IRC base, lists hot-dipped galvanized steel, stainless steel or copper for deck fasteners and hangers. We follow the hanger and fastener makers’ ratings for the lumber treatment on each job.
Talk it through with us
Send a few photos or book a visit and we’ll walk you through the options for your yard.
Walls a ledger can't be bolted to
A ledger can’t hang on brick or stone veneer or on a cantilevered floor, and on those houses the deck either gets its own beam and posts beside the wall or a reworked connection. Lowell’s guide is blunt about it: no ledger on brick veneer, stone veneer or a cantilevered exterior wall, and neither may carry any part of the deck. The City of Greenwood, Indiana, in its prescriptive deck construction guide, lists the options when you still want the deck attached through veneer: support the veneer above on a steel lintel and remove it at the ledger, remove it and block back to the framing, or use an engineered product made for the purpose. A ledger on a cantilevered floor there needs a sealed design from a registered professional.
Plenty of Cincinnati homes have exactly these walls. Brick-veneer ranches on the West Side, brick Tudors in older suburbs, and newer two-stories where the kitchen bump-out cantilevers past the foundation all fall into this group. For most of them, we build a freestanding deck: a beam on its own posts a few inches off the house, with footings dug to frost depth like the rest. It costs a little more in posts and concrete and saves cutting into the wall.
Attached decks also need a lateral connection that keeps the deck from pulling away from the house, which Lowell’s guide points to in Section R507.9.2. That connection is typically made with tension hardware tying deck joists to the house floor framing, and it appears on the plans next to the ledger detail.
Plenty of Cincinnati homes have exactly these walls. Brick-veneer ranches on the West Side, brick Tudors in older suburbs, and newer two-stories where the kitchen bump-out cantilevers past the foundation all fall into this group. For most of them, we build a freestanding deck: a beam on its own posts a few inches off the house, with footings dug to frost depth like the rest. It costs a little more in posts and concrete and saves cutting into the wall.
Attached decks also need a lateral connection that keeps the deck from pulling away from the house, which Lowell’s guide points to in Section R507.9.2. That connection is typically made with tension hardware tying deck joists to the house floor framing, and it appears on the plans next to the ledger detail.
Why ledgers fail on older decks
Most ledger failures we see trace back to one of four things: nails instead of bolts, no flashing, a rotted band joist behind the ledger, or fasteners that have corroded away. NADRA’s Check Your Deck consumer checklist touches all four. It notes that a ledger should not be fastened with nails alone, that flashing keeps moisture and debris from collecting between the house and the ledger, and that rusted or corroded fasteners can damage the wood around them.
You can do a first check yourself. NADRA suggests standing under the deck and looking for metal flashing along the top of the ledger. Look for bolt heads or lag heads at regular spacing, and for dark staining, soft wood or a gap opening between the ledger and the house. A screwdriver that sinks easily into the ledger or the framing around it is a warning sign. A deck that sways or bounces when you walk it is another. NADRA is clear that its checklist doesn’t make a deck code compliant; it is a prompt to call a professional.
If something looks wrong, our deck inspection service checks the ledger connection, the band joist behind it and the rest of the structure, and tells you whether the deck can be repaired or should be replaced. Any repair we propose is based on what we find in person, since photos can’t show the inside of a band joist. We inspect across Hamilton County and the rest of the tri-state.
You can do a first check yourself. NADRA suggests standing under the deck and looking for metal flashing along the top of the ledger. Look for bolt heads or lag heads at regular spacing, and for dark staining, soft wood or a gap opening between the ledger and the house. A screwdriver that sinks easily into the ledger or the framing around it is a warning sign. A deck that sways or bounces when you walk it is another. NADRA is clear that its checklist doesn’t make a deck code compliant; it is a prompt to call a professional.
If something looks wrong, our deck inspection service checks the ledger connection, the band joist behind it and the rest of the structure, and tells you whether the deck can be repaired or should be replaced. Any repair we propose is based on what we find in person, since photos can’t show the inside of a band joist. We inspect across Hamilton County and the rest of the tri-state.
- Look up under the deck for metal flashing over the ledger
- Count bolt or lag heads, and look for any spot that has only nails
- Check for dark streaks or soft wood at the ledger and band joist
- Watch for a gap growing between the ledger and the house
- Look for rust bleeding from fasteners and hangers
- Notice any sway or bounce when people walk the deck
Lit second-story composite deck above a screened under-deck room on a brick home at dusk
What happens to the ledger at inspection
The ledger is checked at the framing inspection, after it is installed and before any decking goes down. Franklin County’s guide lists the ledger among the framing members inspected at that stage, alongside posts, beams and joists. On our jobs the inspector sees the flashing, the fastener pattern and the lateral hardware exposed, and we don’t lay a board until that inspection passes.
When we replace an older deck, the band joist behind the old ledger gets inspected by us first, because new bolts in rotted wood fix nothing. If the rim is soft, it is repaired before the new ledger goes on, and that work is priced in the proposal rather than discovered halfway through. Tearing off and hauling away the old deck costs nothing when the new one has the same footprint or a bigger one. Design, permits, construction and the inspections are part of every proposal, and with the permit issued, the build itself usually runs one to three weeks; design, material deliveries and rain decide where in that window yours lands.
When we replace an older deck, the band joist behind the old ledger gets inspected by us first, because new bolts in rotted wood fix nothing. If the rim is soft, it is repaired before the new ledger goes on, and that work is priced in the proposal rather than discovered halfway through. Tearing off and hauling away the old deck costs nothing when the new one has the same footprint or a bigger one. Design, permits, construction and the inspections are part of every proposal, and with the permit issued, the build itself usually runs one to three weeks; design, material deliveries and rain decide where in that window yours lands.
Related reading
How Deep Do Deck Footings Go in Cincinnati? The Frost Line
From our guide: Deck Permits, Codes and Inspections in the Cincinnati Tri-State.
What Happens at a Deck Inspection: Footing, Framing, Final
From our guide: Deck Permits, Codes and Inspections in the Cincinnati Tri-State.
Deck Railing Height Code in Ohio, Kentucky and Indiana
From our guide: Deck Permits, Codes and Inspections in the Cincinnati Tri-State.
Deck ledger questions
How far apart should ledger bolts be on a deck in Ohio?
It depends on joist span. Under the 2019 Residential Code of Ohio table, half-inch through-bolts with up to half an inch of sheathing go 36 inches apart for joists up to 8 feet, 29 inches for 10 to 12 feet, and 19 inches for 16 to 18 feet. Lag screws need closer spacing.
Can a deck ledger be nailed to the house?
No. The Ohio code language quoted by the City of Columbus rules out toenails and nails subject to withdrawal for the deck-to-house attachment, and NADRA’s checklist says a ledger should not be fastened with nails alone. We use lag screws or through-bolts on the code schedule.
Can you attach a deck to a brick house in Cincinnati?
Not through the brick veneer itself. On brick-veneer homes, which are common around Cincinnati, we usually build the deck freestanding on its own beam and posts beside the wall, or rework the wall at the ledger line so the bolts reach the framing.
What does deck ledger flashing do?
It sheds water that runs down the wall away from the joint between the ledger and the house, so the band joist behind the ledger stays dry. Without it, that framing can rot where you can’t see it, which is one of the most common reasons older decks loosen from the house.
Do Kentucky and Indiana use the same ledger rules as Ohio?
Their deck sections come from the same International Residential Code family, so the approach is familiar, but Kentucky’s 2018 code is based on the 2015 IRC and Indiana’s 2020 code on the 2018 IRC. Across the tri-state we draw to whichever edition the reviewing county enforces.
Sources
Franklin County, Ohio: guide to deck permits (2019 RCO Tables 507.9.1.3(1) and (2), framing inspection)
City of Columbus: Construction Industry Communication #23, decks and exterior egress (RCO 502.2.2, 703.8)
NADRA: Check Your Deck consumer checklist
Town of Lowell, Indiana: residential deck guide (ledger limits, lateral attachment, fastener materials)
City of Greenwood, Indiana: prescriptive deck construction guide (ledgers on masonry veneer and cantilevers)
City of Columbus: Construction Industry Communication #23, decks and exterior egress (RCO 502.2.2, 703.8)
NADRA: Check Your Deck consumer checklist
Town of Lowell, Indiana: residential deck guide (ledger limits, lateral attachment, fastener materials)
City of Greenwood, Indiana: prescriptive deck construction guide (ledgers on masonry veneer and cantilevers)